Ministry of Heavy Industries, Government of India

Battery Test Systems

Home / Battery Test Systems

Power Analyzer (4-Channel)

High precision 4-channel power analyzer used for electrical measurements, efficiency analysis and performance evaluation.

S. N. Parameter Specifications
1 Power Frequency Range DC, 0.5Hz to 200kHz
2 Input Elements 4 Channel Voltage, 4 Channel Current
3 Voltage Range 1V–1000V AC/DC
4 Current Range (External Sensor Input) 1A–1000A AC/DC
5 Basic Voltage/Current/Power Accuracy 0.05%
6 Main Measurement Parameters Voltage (U), Current (I), Active Power (P), Apparent Power (S), Reactive Power (Q), Power Factor, Phase Angle, Frequency, Efficiency, Loss, Voltage Ripple Factor and Current Ripple Factor.
Power Analyzer

Bench Top Climatic Chamber

S. N. Parameter Specifications
1 Temperature Range -40°C to +150°C
2 Test Area (Min Size) inside Chamber 300x350x300mm
3 Input Power Supply 230V AC, 50/60Hz single Phase or 415 V AC 50/60Hz 3Phase
4 Internal Volume of the Chamber 64 L
5 Ramp Rate Ramp Up 2.5°C/Min, Ramp Down 1.5°C/Min
6 Humidity Range 30-95% RH
Bench Top Climatic Chamber

Mechanical Shock Tester

S. N. Parameter Specifications
1 Type Pneumatic
2 Table Size 500x500mm
3 Pulse Duration 1ms to 100ms
4 Acceleration Levels Up to 500g
5 Max DUT Weight 100KG
6 Type Of Shock Half Sine, Trapizoidal, Saw Tooth
Mechanical Shock Tester

Vibration Shaker

S. N. Parameter Specifications
1 Load Rating / Sine Force Peak 6,000 kgf
2 Random Force RMS 6,000 kgf
3 Shock Force 12,000 kgf
4 Armature Resonance ≥ 2000Hz
5 Armature Weight ≤ 60 kg
6 Useful Frequency Range 2000Hz
7 Max Acceleration 100g
8 Displacement (Peak to Peak) 75mm Shock, 68mm Sine
9 Payload (Excluding Extender) 1000kg with VLS else 650 kg
10 Accelerometers 02 Uniaxial, 02 Triaxial
Vibration Shaker

Salt Spray Chamber

S. N. Parameter Specifications
1 Internal Dimensions 0.8×0.6×0.8m
2 Operating Temperature/ Humidity 5°C to 50°C/ 0-95%RH
3 Saturator Tower Temperature Range 5°C to 70°C
4 Saturator (Bubble) Tower Pressure 29kPa-196kPa
5 Fog Collection Range 1-2ml/Hour (For 16 Hr. of test)
Salt Spray Chamber

High Precision DC Power Supply

S. N. Parameter Specifications
1 Low Voltage/ High Current Load1 0-150V DC/ 0-800A DC & Power 8kW
2 Low Voltage/ High Current Load2 0-600V DC/ 0-1400A DC & Power 20kW
3 High Voltage/ Low Current Load1 0-1200V DC/ 0-960A DC & Power 24kW
4 High Voltage/ Low Current Load2 0-600V DC/ 0-500A DC & Power 8kW
5 Operating Conditions 5°C to 40°C/ >80%RH
High Precision DC Power Supply